Exp 2: Non-enzymatic browning reactions and its determination

Step0: Make yourself familiar with the instruments & glassware

juicer CentrifugeSpectrometer Cuvettes Centrifuge tube Strainer

Step1: Extract juice from selected fruit/vegetable

click to put into juicer
Click to turn on juicer

Step2: Filtration of juice sample

click to put strainer
click to filter juice

Step3: Pipette out 5ml strained juice and add into the centrifuge tube A

click to pipette out juice 0000uL
A

Step4: Heat strained juice & take 5ml of it in a centrifuge tube B

click to pipette out juice 0000uL
Heat Juice
B

step5: Add 5ml of 95% ethyl alcohol in both centrifuge tubes

A
B
click to pipette out alcohol 0000uL

Step6: Put both A and B tubes in the centrifuge machine and centrifuge it for 10 min at 5000rpm

Open Centrifuge
Place Sample A
Place Sample B
Close Lid
RPM 100 TIM 1

Step7: Pipette out 1ml of supernatant from the centrifuge tubes and add to the seperate cuvettes

B
A
A
B
click to pipette out 0000uL

Step8: Add 1 ml of 95% ethyl alcohol to 2 other cubettes

click to pipette out 0000uL

Step9: Switch on the UV-vis spectrophotometer and set the wavelength at 420 nm & calibrate it using ethyl alcohol cuvettes

λ=280
Abs=0
place cuvettes
Close Lid
Press read

Step10: Replace one ethyl alcohol cuvette (A&B) with supernatant cuvette and measure the absorbance

λ=420
Abs=0.1275
Open Lid
Replace cuvettes
Press read

Step11: Observation & Result

Observation

Sample Absorbance
Fresh Apple Juice (A) 0.7312
Heated Apple Juice (B) 0.9147

Result

NeBI of fresh apple juice is = 0.7312

NeBI of heated apple juice is = 0.9147

Conclusion

Results indicated that thermal treatment of juices increase the NeBI value of the sample